Single acting pneumatic cylinder operation using 3/2 direction control valve.

Problem Description: -

The operation of Single acting pneumatic cylinder by using two pushbuttons PB1 and PB2. PB1 is for start the operation and PB2 is for stop the operation.

Diagram: -










Here we took Single acting cylinder and 3/2 single solenoid spring return valve now we have to use electric circuit to operate solenoid.

 

Program: -

Here is PLC program for making START/STOP pneumatic cylinder operation using PLC.

 

List of Inputs/Outputs

List of Inputs

X0: -PB1

X1: -PB2

List of Outputs

Y0: -Cylinder Relay output

Ladder Diagram for single acting pneumatic cylinder operation using 3/2 direction control valve.







Program Description: -

-In the ladder diagram, we use two push button one for start (PB1) and other one to stop (PB2). And we also use relay for operate solenoid as shown in figure.

-We give direct 24 voltage to PB1 (NO) and then PB1 normally open contact to PB2 (NC) and then PB2 normally closed contact to the relay.

-Now we take one normally open contact of relay and give to the PB2 common to give continuous supply to the relay it is called latching and take second normally open contact of relay to the solenoid and give 0v to solenoid to complete circuit.

-Now when we press PB1 power supply to the relay and relay start. And by starting relay solenoid is also get power and operate valve. Now if we release PB1 but power to the solenoid will not stop because of latching.

-Now when we press PB2 contact will open stop the relay that’s why solenoid is also stop and cylinder will back at their normal position because of spring return valve.

                                                                                    By Mansuri Afnan